Search with new Tree - Test
Search with new Tree
Test Results
#71 Failed 429
2025-12-06 11:10:45 (8.72s)
AI: The test failed because the API returned a rate limit exceeded error (HTTP 429) instead of the expected product compliance data (HTTP 200).
Expected status 200, got 429
AI Functional Analysis
Summary
The test failed because the API returned a rate limit exceeded error (HTTP 429) instead of the expected product compliance data (HTTP 200).
Detailed Report
Visual Difference
{
"details": {
"limit": 10,
"retry_after": 60,
"window_seconds": 60
},
"error": "Rate limit exceeded",
"error_code": "RATE_LIMIT_EXCEEDED"
}
{
"compliance_analysis": {
"alerts": [
"RoHS Exemption 7(c)-I (Lead in glass/ceramic) is claimed.",
"RoHS Exemption 10(a) is also listed in the document but is typically for ELV or specific applications; 7(c)-I is the primary RoHS exemption for resistors.",
"Full material composition breakdown (IPC-1752) not available; partial substance data extracted from RoHS/REACH certificates."
],
"compliance_summary": "RoHS Compliant with Exemptions 7(c)-I and 10(a). REACH Compliant (SVHC \u003c 0.1%). Source: RoHS Exempt - \u0027It is hereby certified that all of the electronic components stated above are compliant with EU RoHS... We also claim for the following exemption... 7(c)-1: Electrical and electronics compounds... containing Lead in a glass or ceramic...\u0027. REACH Declaration - \u0027COMPLY WITH the Regulations of Substances of Very High Concern... (SVHC\u003c0.1%)\u0027. The MPN RC0603FR-0710KL belongs to the RC series covered by the RoHS exemption document.",
"confidence_level": "high",
"created_at": "2025-12-03T18:12:05.351829",
"critical_issues": [],
"documents_analyzed": 9,
"material_composition": {
"date_of_issue": "2024-05-13",
"format_standard": "Manufacturer Declaration",
"mpn_verified": true,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "RC0603FR-0710KL-RoHS Exempt",
"extraction_confidence": "medium"
},
"substances": [
{
"cas_number": "7439-92-1",
"concentration": "\u003c 90 ppm",
"name": "Lead",
"purpose": "Termination coating",
"threshold_exceeded": false
},
{
"cas_number": "7440-43-9",
"concentration": "\u003c 2 ppm",
"name": "Cadmium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "7439-97-6",
"concentration": "\u003c 2 ppm",
"name": "Mercury",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "18540-29-9",
"concentration": "\u003c 8 ppm",
"name": "Hexavalent Chromium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBBs",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBDE",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "117-81-7",
"concentration": "\u003c 50 ppm",
"name": "DEHP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-74-2",
"concentration": "\u003c 50 ppm",
"name": "DBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "85-68-7",
"concentration": "\u003c 50 ppm",
"name": "BBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-69-5",
"concentration": "\u003c 50 ppm",
"name": "DIBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
]
},
"mpn": "RC0603FR-0710KL",
"overall_compliance_status": "compliant_with_exemptions",
"reach_analysis": {
"candidate_list_date": "2025-06-25",
"compliance_status": "compliant",
"critical_substance_alert": false,
"date_of_issue": "2025-02-04",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": null,
"exist_exceptions_limitations": false,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "Chip Resistor",
"revised_date": null,
"source": {
"document_level": "specific",
"document_type": "REACH",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf",
"extraction_confidence": "high"
},
"svhc_cas_numbers": [],
"svhc_present": false,
"svhc_substances": [],
"version": {
"date": "2006-12-18",
"details": "Regulation (EC) No 1907/2006",
"name": "REACH"
},
"version_too_old": false
},
"rohs_analysis": {
"compliance_status": "compliant_with_exemptions",
"critical_substance_alert": false,
"date_of_issue": "2024-05-13",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": {
"conditions": "Lead in a glass or ceramic, or in a glass or ceramic matrix compound",
"exemption_codes": [
"7(c)-I",
"10(a)"
],
"expiry_dates": null,
"geographic_scope": [
"EU",
"China"
],
"has_exemptions": true,
"used_substances": [
{
"cas_number": "7439-92-1",
"concentration": null,
"name": "Lead",
"purpose": "In glass or ceramic matrix",
"threshold_exceeded": true
}
],
"uses_substances": true
},
"exist_exceptions_limitations": true,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "R-CHIP (RC Series)",
"revised_date": null,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"extraction_confidence": "high"
},
"version": {
"date": "2015-06-04",
"details": "Directive (EU) 2015/863",
"name": "RoHS III"
},
"version_too_old": false
}
},
"documents": [
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Company",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:27.079534",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Company",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:27.079542",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "Conflict Minerals",
"uploaded_at": "2025-12-03T18:08:27.079547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/conflict_minerals_caa1f494.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "California Proposition 65",
"uploaded_at": "2025-12-03T18:08:27.079551",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/california_proposition_65_8e8146f6.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "TSCA",
"uploaded_at": "2025-12-03T18:08:27.079555",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/tsca_42bcc7a4.pdf"
},
{
"doc_metadata": null,
"level": "Component",
"type": "Datasheet",
"uploaded_at": "2025-12-03T18:08:41.008113",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/datasheet_b76ea769.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Component",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:41.008402",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_75ab3f76.pdf"
},
{
"doc_metadata": null,
"level": "Series",
"type": "Halogen-Free",
"uploaded_at": "2025-12-03T18:08:41.008547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/halogen-free_1c89b3e7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.043987",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_be38c8a6.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.044217",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_89f2a1db.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044426",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_621bb13a.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044660",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_225fdd52.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044814",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_807860ec.pdf"
}
],
"internal_id": null,
"manufacturer": "YAGEO",
"mpn": "RC0603FR-0710KL",
"processing_time_ms": 0,
"product_url": "https://www.yageogroup.com/products/Resistors/part/RC0603FR-0710KL",
"status": "active"
}
#51 Failed 429
2025-12-06 11:10:44 (6.55s)
AI: The test failed due to a rate limit being exceeded, preventing the system from returning the expected product data and compliance analysis.
Expected status 200, got 429
AI Functional Analysis
Summary
The test failed due to a rate limit being exceeded, preventing the system from returning the expected product data and compliance analysis.
Detailed Report
Visual Difference
{
"details": {
"limit": 10,
"retry_after": 60,
"window_seconds": 60
},
"error": "Rate limit exceeded",
"error_code": "RATE_LIMIT_EXCEEDED"
}
{
"compliance_analysis": {
"alerts": [
"RoHS Exemption 7(c)-I (Lead in glass/ceramic) is claimed.",
"RoHS Exemption 10(a) is also listed in the document but is typically for ELV or specific applications; 7(c)-I is the primary RoHS exemption for resistors.",
"Full material composition breakdown (IPC-1752) not available; partial substance data extracted from RoHS/REACH certificates."
],
"compliance_summary": "RoHS Compliant with Exemptions 7(c)-I and 10(a). REACH Compliant (SVHC \u003c 0.1%). Source: RoHS Exempt - \u0027It is hereby certified that all of the electronic components stated above are compliant with EU RoHS... We also claim for the following exemption... 7(c)-1: Electrical and electronics compounds... containing Lead in a glass or ceramic...\u0027. REACH Declaration - \u0027COMPLY WITH the Regulations of Substances of Very High Concern... (SVHC\u003c0.1%)\u0027. The MPN RC0603FR-0710KL belongs to the RC series covered by the RoHS exemption document.",
"confidence_level": "high",
"created_at": "2025-12-03T18:12:05.351829",
"critical_issues": [],
"documents_analyzed": 9,
"material_composition": {
"date_of_issue": "2024-05-13",
"format_standard": "Manufacturer Declaration",
"mpn_verified": true,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "RC0603FR-0710KL-RoHS Exempt",
"extraction_confidence": "medium"
},
"substances": [
{
"cas_number": "7439-92-1",
"concentration": "\u003c 90 ppm",
"name": "Lead",
"purpose": "Termination coating",
"threshold_exceeded": false
},
{
"cas_number": "7440-43-9",
"concentration": "\u003c 2 ppm",
"name": "Cadmium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "7439-97-6",
"concentration": "\u003c 2 ppm",
"name": "Mercury",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "18540-29-9",
"concentration": "\u003c 8 ppm",
"name": "Hexavalent Chromium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBBs",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBDE",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "117-81-7",
"concentration": "\u003c 50 ppm",
"name": "DEHP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-74-2",
"concentration": "\u003c 50 ppm",
"name": "DBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "85-68-7",
"concentration": "\u003c 50 ppm",
"name": "BBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-69-5",
"concentration": "\u003c 50 ppm",
"name": "DIBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
]
},
"mpn": "RC0603FR-0710KL",
"overall_compliance_status": "compliant_with_exemptions",
"reach_analysis": {
"candidate_list_date": "2025-06-25",
"compliance_status": "compliant",
"critical_substance_alert": false,
"date_of_issue": "2025-02-04",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": null,
"exist_exceptions_limitations": false,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "Chip Resistor",
"revised_date": null,
"source": {
"document_level": "specific",
"document_type": "REACH",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf",
"extraction_confidence": "high"
},
"svhc_cas_numbers": [],
"svhc_present": false,
"svhc_substances": [],
"version": {
"date": "2006-12-18",
"details": "Regulation (EC) No 1907/2006",
"name": "REACH"
},
"version_too_old": false
},
"rohs_analysis": {
"compliance_status": "compliant_with_exemptions",
"critical_substance_alert": false,
"date_of_issue": "2024-05-13",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": {
"conditions": "Lead in a glass or ceramic, or in a glass or ceramic matrix compound",
"exemption_codes": [
"7(c)-I",
"10(a)"
],
"expiry_dates": null,
"geographic_scope": [
"EU",
"China"
],
"has_exemptions": true,
"used_substances": [
{
"cas_number": "7439-92-1",
"concentration": null,
"name": "Lead",
"purpose": "In glass or ceramic matrix",
"threshold_exceeded": true
}
],
"uses_substances": true
},
"exist_exceptions_limitations": true,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "R-CHIP (RC Series)",
"revised_date": null,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"extraction_confidence": "high"
},
"version": {
"date": "2015-06-04",
"details": "Directive (EU) 2015/863",
"name": "RoHS III"
},
"version_too_old": false
}
},
"documents": [
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Company",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:27.079534",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Company",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:27.079542",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "Conflict Minerals",
"uploaded_at": "2025-12-03T18:08:27.079547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/conflict_minerals_caa1f494.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "California Proposition 65",
"uploaded_at": "2025-12-03T18:08:27.079551",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/california_proposition_65_8e8146f6.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "TSCA",
"uploaded_at": "2025-12-03T18:08:27.079555",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/tsca_42bcc7a4.pdf"
},
{
"doc_metadata": null,
"level": "Component",
"type": "Datasheet",
"uploaded_at": "2025-12-03T18:08:41.008113",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/datasheet_b76ea769.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Component",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:41.008402",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_75ab3f76.pdf"
},
{
"doc_metadata": null,
"level": "Series",
"type": "Halogen-Free",
"uploaded_at": "2025-12-03T18:08:41.008547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/halogen-free_1c89b3e7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.043987",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_be38c8a6.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.044217",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_89f2a1db.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044426",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_621bb13a.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044660",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_225fdd52.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044814",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_807860ec.pdf"
}
],
"internal_id": null,
"manufacturer": "YAGEO",
"mpn": "RC0603FR-0710KL",
"processing_time_ms": 0,
"product_url": "https://www.yageogroup.com/products/Resistors/part/RC0603FR-0710KL",
"status": "active"
}
#37 Failed 429
2025-12-06 11:10:15 (5.50s)
AI: The test failed due to a rate limit violation (HTTP 429 Spike Arrest), preventing the system from returning the expected product data and thus making the functional correctness unverifiable.
Expected status 200, got 429
AI Functional Analysis
Summary
The test failed due to a rate limit violation (HTTP 429 Spike Arrest), preventing the system from returning the expected product data and thus making the functional correctness unverifiable.
Detailed Report
Visual Difference
{
"fault": {
"detail": {
"errorcode": "policies.ratelimit.SpikeArrestViolation"
},
"faultstring": "Spike arrest violation. Allowed rate : MessageRate{messagesPerPeriod=30, periodInMicroseconds=1000000, maxBurstMessageCount=3.0}"
}
}
{
"compliance_analysis": {
"alerts": [
"RoHS Exemption 7(c)-I (Lead in glass/ceramic) is claimed.",
"RoHS Exemption 10(a) is also listed in the document but is typically for ELV or specific applications; 7(c)-I is the primary RoHS exemption for resistors.",
"Full material composition breakdown (IPC-1752) not available; partial substance data extracted from RoHS/REACH certificates."
],
"compliance_summary": "RoHS Compliant with Exemptions 7(c)-I and 10(a). REACH Compliant (SVHC \u003c 0.1%). Source: RoHS Exempt - \u0027It is hereby certified that all of the electronic components stated above are compliant with EU RoHS... We also claim for the following exemption... 7(c)-1: Electrical and electronics compounds... containing Lead in a glass or ceramic...\u0027. REACH Declaration - \u0027COMPLY WITH the Regulations of Substances of Very High Concern... (SVHC\u003c0.1%)\u0027. The MPN RC0603FR-0710KL belongs to the RC series covered by the RoHS exemption document.",
"confidence_level": "high",
"created_at": "2025-12-03T18:12:05.351829",
"critical_issues": [],
"documents_analyzed": 9,
"material_composition": {
"date_of_issue": "2024-05-13",
"format_standard": "Manufacturer Declaration",
"mpn_verified": true,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "RC0603FR-0710KL-RoHS Exempt",
"extraction_confidence": "medium"
},
"substances": [
{
"cas_number": "7439-92-1",
"concentration": "\u003c 90 ppm",
"name": "Lead",
"purpose": "Termination coating",
"threshold_exceeded": false
},
{
"cas_number": "7440-43-9",
"concentration": "\u003c 2 ppm",
"name": "Cadmium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "7439-97-6",
"concentration": "\u003c 2 ppm",
"name": "Mercury",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "18540-29-9",
"concentration": "\u003c 8 ppm",
"name": "Hexavalent Chromium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBBs",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBDE",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "117-81-7",
"concentration": "\u003c 50 ppm",
"name": "DEHP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-74-2",
"concentration": "\u003c 50 ppm",
"name": "DBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "85-68-7",
"concentration": "\u003c 50 ppm",
"name": "BBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-69-5",
"concentration": "\u003c 50 ppm",
"name": "DIBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
]
},
"mpn": "RC0603FR-0710KL",
"overall_compliance_status": "compliant_with_exemptions",
"reach_analysis": {
"candidate_list_date": "2025-06-25",
"compliance_status": "compliant",
"critical_substance_alert": false,
"date_of_issue": "2025-02-04",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": null,
"exist_exceptions_limitations": false,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "Chip Resistor",
"revised_date": null,
"source": {
"document_level": "specific",
"document_type": "REACH",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf",
"extraction_confidence": "high"
},
"svhc_cas_numbers": [],
"svhc_present": false,
"svhc_substances": [],
"version": {
"date": "2006-12-18",
"details": "Regulation (EC) No 1907/2006",
"name": "REACH"
},
"version_too_old": false
},
"rohs_analysis": {
"compliance_status": "compliant_with_exemptions",
"critical_substance_alert": false,
"date_of_issue": "2024-05-13",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": {
"conditions": "Lead in a glass or ceramic, or in a glass or ceramic matrix compound",
"exemption_codes": [
"7(c)-I",
"10(a)"
],
"expiry_dates": null,
"geographic_scope": [
"EU",
"China"
],
"has_exemptions": true,
"used_substances": [
{
"cas_number": "7439-92-1",
"concentration": null,
"name": "Lead",
"purpose": "In glass or ceramic matrix",
"threshold_exceeded": true
}
],
"uses_substances": true
},
"exist_exceptions_limitations": true,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "R-CHIP (RC Series)",
"revised_date": null,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"extraction_confidence": "high"
},
"version": {
"date": "2015-06-04",
"details": "Directive (EU) 2015/863",
"name": "RoHS III"
},
"version_too_old": false
}
},
"documents": [
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Company",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:27.079534",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Company",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:27.079542",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "Conflict Minerals",
"uploaded_at": "2025-12-03T18:08:27.079547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/conflict_minerals_caa1f494.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "California Proposition 65",
"uploaded_at": "2025-12-03T18:08:27.079551",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/california_proposition_65_8e8146f6.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "TSCA",
"uploaded_at": "2025-12-03T18:08:27.079555",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/tsca_42bcc7a4.pdf"
},
{
"doc_metadata": null,
"level": "Component",
"type": "Datasheet",
"uploaded_at": "2025-12-03T18:08:41.008113",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/datasheet_b76ea769.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Component",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:41.008402",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_75ab3f76.pdf"
},
{
"doc_metadata": null,
"level": "Series",
"type": "Halogen-Free",
"uploaded_at": "2025-12-03T18:08:41.008547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/halogen-free_1c89b3e7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.043987",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_be38c8a6.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.044217",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_89f2a1db.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044426",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_621bb13a.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044660",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_225fdd52.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044814",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_807860ec.pdf"
}
],
"internal_id": null,
"manufacturer": "YAGEO",
"mpn": "RC0603FR-0710KL",
"processing_time_ms": 0,
"product_url": "https://www.yageogroup.com/products/Resistors/part/RC0603FR-0710KL",
"status": "active"
}
#13 Passed 200
2025-12-05 19:55:58 (6.88s)
AI: The actual response perfectly matched the expected response for the 'Search with new Tree - Test' test case.
AI Functional Analysis
Summary
The actual response perfectly matched the expected response for the 'Search with new Tree - Test' test case.
Detailed Report
Visual Difference
{
"compliance_analysis": {
"alerts": [
"RoHS Exemption 7(c)-I (Lead in glass/ceramic) is claimed.",
"RoHS Exemption 10(a) is also listed in the document but is typically for ELV or specific applications; 7(c)-I is the primary RoHS exemption for resistors.",
"Full material composition breakdown (IPC-1752) not available; partial substance data extracted from RoHS/REACH certificates."
],
"compliance_summary": "RoHS Compliant with Exemptions 7(c)-I and 10(a). REACH Compliant (SVHC \u003c 0.1%). Source: RoHS Exempt - \u0027It is hereby certified that all of the electronic components stated above are compliant with EU RoHS... We also claim for the following exemption... 7(c)-1: Electrical and electronics compounds... containing Lead in a glass or ceramic...\u0027. REACH Declaration - \u0027COMPLY WITH the Regulations of Substances of Very High Concern... (SVHC\u003c0.1%)\u0027. The MPN RC0603FR-0710KL belongs to the RC series covered by the RoHS exemption document.",
"confidence_level": "high",
"created_at": "2025-12-03T18:12:05.351829",
"critical_issues": [],
"documents_analyzed": 9,
"material_composition": {
"date_of_issue": "2024-05-13",
"format_standard": "Manufacturer Declaration",
"mpn_verified": true,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "RC0603FR-0710KL-RoHS Exempt",
"extraction_confidence": "medium"
},
"substances": [
{
"cas_number": "7439-92-1",
"concentration": "\u003c 90 ppm",
"name": "Lead",
"purpose": "Termination coating",
"threshold_exceeded": false
},
{
"cas_number": "7440-43-9",
"concentration": "\u003c 2 ppm",
"name": "Cadmium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "7439-97-6",
"concentration": "\u003c 2 ppm",
"name": "Mercury",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "18540-29-9",
"concentration": "\u003c 8 ppm",
"name": "Hexavalent Chromium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBBs",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBDE",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "117-81-7",
"concentration": "\u003c 50 ppm",
"name": "DEHP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-74-2",
"concentration": "\u003c 50 ppm",
"name": "DBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "85-68-7",
"concentration": "\u003c 50 ppm",
"name": "BBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-69-5",
"concentration": "\u003c 50 ppm",
"name": "DIBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
]
},
"mpn": "RC0603FR-0710KL",
"overall_compliance_status": "compliant_with_exemptions",
"reach_analysis": {
"candidate_list_date": "2025-06-25",
"compliance_status": "compliant",
"critical_substance_alert": false,
"date_of_issue": "2025-02-04",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": null,
"exist_exceptions_limitations": false,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "Chip Resistor",
"revised_date": null,
"source": {
"document_level": "specific",
"document_type": "REACH",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf",
"extraction_confidence": "high"
},
"svhc_cas_numbers": [],
"svhc_present": false,
"svhc_substances": [],
"version": {
"date": "2006-12-18",
"details": "Regulation (EC) No 1907/2006",
"name": "REACH"
},
"version_too_old": false
},
"rohs_analysis": {
"compliance_status": "compliant_with_exemptions",
"critical_substance_alert": false,
"date_of_issue": "2024-05-13",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": {
"conditions": "Lead in a glass or ceramic, or in a glass or ceramic matrix compound",
"exemption_codes": [
"7(c)-I",
"10(a)"
],
"expiry_dates": null,
"geographic_scope": [
"EU",
"China"
],
"has_exemptions": true,
"used_substances": [
{
"cas_number": "7439-92-1",
"concentration": null,
"name": "Lead",
"purpose": "In glass or ceramic matrix",
"threshold_exceeded": true
}
],
"uses_substances": true
},
"exist_exceptions_limitations": true,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "R-CHIP (RC Series)",
"revised_date": null,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"extraction_confidence": "high"
},
"version": {
"date": "2015-06-04",
"details": "Directive (EU) 2015/863",
"name": "RoHS III"
},
"version_too_old": false
}
},
"documents": [
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Company",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:27.079534",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Company",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:27.079542",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "Conflict Minerals",
"uploaded_at": "2025-12-03T18:08:27.079547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/conflict_minerals_caa1f494.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "California Proposition 65",
"uploaded_at": "2025-12-03T18:08:27.079551",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/california_proposition_65_8e8146f6.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "TSCA",
"uploaded_at": "2025-12-03T18:08:27.079555",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/tsca_42bcc7a4.pdf"
},
{
"doc_metadata": null,
"level": "Component",
"type": "Datasheet",
"uploaded_at": "2025-12-03T18:08:41.008113",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/datasheet_b76ea769.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Component",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:41.008402",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_75ab3f76.pdf"
},
{
"doc_metadata": null,
"level": "Series",
"type": "Halogen-Free",
"uploaded_at": "2025-12-03T18:08:41.008547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/halogen-free_1c89b3e7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.043987",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_be38c8a6.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.044217",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_89f2a1db.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044426",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_621bb13a.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044660",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_225fdd52.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044814",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_807860ec.pdf"
}
],
"internal_id": null,
"manufacturer": "YAGEO",
"mpn": "RC0603FR-0710KL",
"processing_time_ms": 0,
"product_url": "https://www.yageogroup.com/products/Resistors/part/RC0603FR-0710KL",
"status": "active"
}
{
"compliance_analysis": {
"alerts": [
"RoHS Exemption 7(c)-I (Lead in glass/ceramic) is claimed.",
"RoHS Exemption 10(a) is also listed in the document but is typically for ELV or specific applications; 7(c)-I is the primary RoHS exemption for resistors.",
"Full material composition breakdown (IPC-1752) not available; partial substance data extracted from RoHS/REACH certificates."
],
"compliance_summary": "RoHS Compliant with Exemptions 7(c)-I and 10(a). REACH Compliant (SVHC \u003c 0.1%). Source: RoHS Exempt - \u0027It is hereby certified that all of the electronic components stated above are compliant with EU RoHS... We also claim for the following exemption... 7(c)-1: Electrical and electronics compounds... containing Lead in a glass or ceramic...\u0027. REACH Declaration - \u0027COMPLY WITH the Regulations of Substances of Very High Concern... (SVHC\u003c0.1%)\u0027. The MPN RC0603FR-0710KL belongs to the RC series covered by the RoHS exemption document.",
"confidence_level": "high",
"created_at": "2025-12-03T18:12:05.351829",
"critical_issues": [],
"documents_analyzed": 9,
"material_composition": {
"date_of_issue": "2024-05-13",
"format_standard": "Manufacturer Declaration",
"mpn_verified": true,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "RC0603FR-0710KL-RoHS Exempt",
"extraction_confidence": "medium"
},
"substances": [
{
"cas_number": "7439-92-1",
"concentration": "\u003c 90 ppm",
"name": "Lead",
"purpose": "Termination coating",
"threshold_exceeded": false
},
{
"cas_number": "7440-43-9",
"concentration": "\u003c 2 ppm",
"name": "Cadmium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "7439-97-6",
"concentration": "\u003c 2 ppm",
"name": "Mercury",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "18540-29-9",
"concentration": "\u003c 8 ppm",
"name": "Hexavalent Chromium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBBs",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBDE",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "117-81-7",
"concentration": "\u003c 50 ppm",
"name": "DEHP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-74-2",
"concentration": "\u003c 50 ppm",
"name": "DBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "85-68-7",
"concentration": "\u003c 50 ppm",
"name": "BBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-69-5",
"concentration": "\u003c 50 ppm",
"name": "DIBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
]
},
"mpn": "RC0603FR-0710KL",
"overall_compliance_status": "compliant_with_exemptions",
"reach_analysis": {
"candidate_list_date": "2025-06-25",
"compliance_status": "compliant",
"critical_substance_alert": false,
"date_of_issue": "2025-02-04",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": null,
"exist_exceptions_limitations": false,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "Chip Resistor",
"revised_date": null,
"source": {
"document_level": "specific",
"document_type": "REACH",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf",
"extraction_confidence": "high"
},
"svhc_cas_numbers": [],
"svhc_present": false,
"svhc_substances": [],
"version": {
"date": "2006-12-18",
"details": "Regulation (EC) No 1907/2006",
"name": "REACH"
},
"version_too_old": false
},
"rohs_analysis": {
"compliance_status": "compliant_with_exemptions",
"critical_substance_alert": false,
"date_of_issue": "2024-05-13",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": {
"conditions": "Lead in a glass or ceramic, or in a glass or ceramic matrix compound",
"exemption_codes": [
"7(c)-I",
"10(a)"
],
"expiry_dates": null,
"geographic_scope": [
"EU",
"China"
],
"has_exemptions": true,
"used_substances": [
{
"cas_number": "7439-92-1",
"concentration": null,
"name": "Lead",
"purpose": "In glass or ceramic matrix",
"threshold_exceeded": true
}
],
"uses_substances": true
},
"exist_exceptions_limitations": true,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "R-CHIP (RC Series)",
"revised_date": null,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"extraction_confidence": "high"
},
"version": {
"date": "2015-06-04",
"details": "Directive (EU) 2015/863",
"name": "RoHS III"
},
"version_too_old": false
}
},
"documents": [
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Company",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:27.079534",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Company",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:27.079542",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "Conflict Minerals",
"uploaded_at": "2025-12-03T18:08:27.079547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/conflict_minerals_caa1f494.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "California Proposition 65",
"uploaded_at": "2025-12-03T18:08:27.079551",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/california_proposition_65_8e8146f6.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "TSCA",
"uploaded_at": "2025-12-03T18:08:27.079555",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/tsca_42bcc7a4.pdf"
},
{
"doc_metadata": null,
"level": "Component",
"type": "Datasheet",
"uploaded_at": "2025-12-03T18:08:41.008113",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/datasheet_b76ea769.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Component",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:41.008402",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_75ab3f76.pdf"
},
{
"doc_metadata": null,
"level": "Series",
"type": "Halogen-Free",
"uploaded_at": "2025-12-03T18:08:41.008547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/halogen-free_1c89b3e7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.043987",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_be38c8a6.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.044217",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_89f2a1db.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044426",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_621bb13a.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044660",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_225fdd52.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044814",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_807860ec.pdf"
}
],
"internal_id": null,
"manufacturer": "YAGEO",
"mpn": "RC0603FR-0710KL",
"processing_time_ms": 0,
"product_url": "https://www.yageogroup.com/products/Resistors/part/RC0603FR-0710KL",
"status": "active"
}
Endpoint Details
- Method
- POST
- Parameter Mode
- json
- Endpoint
- /api/v1/compliance/search
- Expected Status
Request Payload
{
"analyze_compliance": "true",
"extract_metadata": "true",
"manufacturer": "yageo",
"mpn": "RC0603FR-0710KL",
"use_cache": "true"
}
Expected Response
{
"compliance_analysis": {
"alerts": [
"RoHS Exemption 7(c)-I (Lead in glass/ceramic) is claimed.",
"RoHS Exemption 10(a) is also listed in the document but is typically for ELV or specific applications; 7(c)-I is the primary RoHS exemption for resistors.",
"Full material composition breakdown (IPC-1752) not available; partial substance data extracted from RoHS/REACH certificates."
],
"compliance_summary": "RoHS Compliant with Exemptions 7(c)-I and 10(a). REACH Compliant (SVHC \u003c 0.1%). Source: RoHS Exempt - \u0027It is hereby certified that all of the electronic components stated above are compliant with EU RoHS... We also claim for the following exemption... 7(c)-1: Electrical and electronics compounds... containing Lead in a glass or ceramic...\u0027. REACH Declaration - \u0027COMPLY WITH the Regulations of Substances of Very High Concern... (SVHC\u003c0.1%)\u0027. The MPN RC0603FR-0710KL belongs to the RC series covered by the RoHS exemption document.",
"confidence_level": "high",
"created_at": "2025-12-03T18:12:05.351829",
"critical_issues": [],
"documents_analyzed": 9,
"material_composition": {
"date_of_issue": "2024-05-13",
"format_standard": "Manufacturer Declaration",
"mpn_verified": true,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "RC0603FR-0710KL-RoHS Exempt",
"extraction_confidence": "medium"
},
"substances": [
{
"cas_number": "7439-92-1",
"concentration": "\u003c 90 ppm",
"name": "Lead",
"purpose": "Termination coating",
"threshold_exceeded": false
},
{
"cas_number": "7440-43-9",
"concentration": "\u003c 2 ppm",
"name": "Cadmium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "7439-97-6",
"concentration": "\u003c 2 ppm",
"name": "Mercury",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "18540-29-9",
"concentration": "\u003c 8 ppm",
"name": "Hexavalent Chromium",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBBs",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": null,
"concentration": "\u003c 5 ppm",
"name": "PBDE",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "117-81-7",
"concentration": "\u003c 50 ppm",
"name": "DEHP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-74-2",
"concentration": "\u003c 50 ppm",
"name": "DBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "85-68-7",
"concentration": "\u003c 50 ppm",
"name": "BBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"cas_number": "84-69-5",
"concentration": "\u003c 50 ppm",
"name": "DIBP",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
]
},
"mpn": "RC0603FR-0710KL",
"overall_compliance_status": "compliant_with_exemptions",
"reach_analysis": {
"candidate_list_date": "2025-06-25",
"compliance_status": "compliant",
"critical_substance_alert": false,
"date_of_issue": "2025-02-04",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": null,
"exist_exceptions_limitations": false,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "Chip Resistor",
"revised_date": null,
"source": {
"document_level": "specific",
"document_type": "REACH",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf",
"extraction_confidence": "high"
},
"svhc_cas_numbers": [],
"svhc_present": false,
"svhc_substances": [],
"version": {
"date": "2006-12-18",
"details": "Regulation (EC) No 1907/2006",
"name": "REACH"
},
"version_too_old": false
},
"rohs_analysis": {
"compliance_status": "compliant_with_exemptions",
"critical_substance_alert": false,
"date_of_issue": "2024-05-13",
"exclusions": {
"conditions": null,
"has_exclusions": false,
"reasons": null,
"used_substances": [],
"uses_substances": false
},
"exemptions": {
"conditions": "Lead in a glass or ceramic, or in a glass or ceramic matrix compound",
"exemption_codes": [
"7(c)-I",
"10(a)"
],
"expiry_dates": null,
"geographic_scope": [
"EU",
"China"
],
"has_exemptions": true,
"used_substances": [
{
"cas_number": "7439-92-1",
"concentration": null,
"name": "Lead",
"purpose": "In glass or ceramic matrix",
"threshold_exceeded": true
}
],
"uses_substances": true
},
"exist_exceptions_limitations": true,
"is_approved": true,
"manufacturer": "YAGEO",
"mpn_coverage": "specific",
"mpn_mentioned": true,
"product_family": "R-CHIP (RC Series)",
"revised_date": null,
"source": {
"document_level": "series",
"document_type": "RoHS Exempt",
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"extraction_confidence": "high"
},
"version": {
"date": "2015-06-04",
"details": "Directive (EU) 2015/863",
"name": "RoHS III"
},
"version_too_old": false
}
},
"documents": [
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Company",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:27.079534",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Company",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:27.079542",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "Conflict Minerals",
"uploaded_at": "2025-12-03T18:08:27.079547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/conflict_minerals_caa1f494.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "California Proposition 65",
"uploaded_at": "2025-12-03T18:08:27.079551",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/california_proposition_65_8e8146f6.pdf"
},
{
"doc_metadata": null,
"level": "Company",
"type": "TSCA",
"uploaded_at": "2025-12-03T18:08:27.079555",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/tsca_42bcc7a4.pdf"
},
{
"doc_metadata": null,
"level": "Component",
"type": "Datasheet",
"uploaded_at": "2025-12-03T18:08:41.008113",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/datasheet_b76ea769.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Component",
"type": "RoHS",
"uploaded_at": "2025-12-03T18:08:41.008402",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_75ab3f76.pdf"
},
{
"doc_metadata": null,
"level": "Series",
"type": "Halogen-Free",
"uploaded_at": "2025-12-03T18:08:41.008547",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/halogen-free_1c89b3e7.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.043987",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_be38c8a6.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant",
"coverage": "specific",
"date_of_issue": "2025-02-04",
"is_approved": true,
"revised_date": null,
"version": null
},
"level": "Series",
"type": "REACH",
"uploaded_at": "2025-12-03T18:08:43.044217",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_89f2a1db.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044426",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_621bb13a.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044660",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_225fdd52.pdf"
},
{
"doc_metadata": {
"compliance_status": "compliant_with_exemptions",
"coverage": "specific",
"date_of_issue": "2024-05-13",
"is_approved": true,
"revised_date": null,
"version": "RoHS III"
},
"level": "Series",
"type": "RoHS Exempt",
"uploaded_at": "2025-12-03T18:08:43.044814",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_807860ec.pdf"
}
],
"internal_id": null,
"manufacturer": "YAGEO",
"mpn": "RC0603FR-0710KL",
"processing_time_ms": 0,
"product_url": "https://www.yageogroup.com/products/Resistors/part/RC0603FR-0710KL",
"status": "active"
}
Validation Rules
| Path | Type | Sample | Status |
|---|---|---|---|
| root | dict |
{
"internal_id": null,
"mpn": "RC0603FR-0710KL",
"manufacturer": "YAGEO",
"status": "active",
"product_url": "https://www.yageogroup.com/products/Resistors/part/RC0603FR-0710KL",
"documents": [
{
"type": "RoHS",
"level": "Company",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"uploaded_at": "2025-12-03T18:08:27.079534",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2024-05-
|
Critical |
| internal_id | None |
None
|
Not Important |
| mpn | str |
RC0603FR-0710KL
|
Not Important |
| manufacturer | str |
YAGEO
|
Not Important |
| status | str |
active
|
Critical |
| product_url | str |
https://www.yageogroup.com/products/Resistors/part/RC0603FR-0710KL
|
Not Important |
| documents | list |
[
{
"type": "RoHS",
"level": "Company",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"uploaded_at": "2025-12-03T18:08:27.079534",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
},
{
"type": "REACH",
"level": "Company",
"url": "h
|
Critical |
| documents[0] | dict |
{
"type": "RoHS",
"level": "Company",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"uploaded_at": "2025-12-03T18:08:27.079534",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
}
|
Not Important |
| documents[0].type | str |
RoHS
|
Not Important |
| documents[0].level | str |
Company
|
Not Important |
| documents[0].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf
|
Critical |
| documents[0].uploaded_at | str |
2025-12-03T18:08:27.079534
|
Not Important |
| documents[0].doc_metadata | dict |
{
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
|
Not Important |
| documents[0].doc_metadata.is_approved | bool |
True
|
Not Important |
| documents[0].doc_metadata.date_of_issue | str |
2024-05-13
|
Not Important |
| documents[0].doc_metadata.revised_date | None |
None
|
Not Important |
| documents[0].doc_metadata.version | str |
RoHS III
|
Not Important |
| documents[0].doc_metadata.coverage | str |
specific
|
Not Important |
| documents[0].doc_metadata.compliance_status | str |
compliant_with_exemptions
|
Not Important |
| documents[1] | dict |
{
"type": "REACH",
"level": "Company",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf",
"uploaded_at": "2025-12-03T18:08:27.079542",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2025-02-04",
"revised_date": null,
"version": null,
"coverage": "specific",
"compliance_status": "compliant"
}
}
|
Not Important |
| documents[1].type | str |
REACH
|
Not Important |
| documents[1].level | str |
Company
|
Not Important |
| documents[1].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf
|
Not Important |
| documents[1].uploaded_at | str |
2025-12-03T18:08:27.079542
|
Not Important |
| documents[1].doc_metadata | dict |
{
"is_approved": true,
"date_of_issue": "2025-02-04",
"revised_date": null,
"version": null,
"coverage": "specific",
"compliance_status": "compliant"
}
|
Not Important |
| documents[1].doc_metadata.is_approved | bool |
True
|
Not Important |
| documents[1].doc_metadata.date_of_issue | str |
2025-02-04
|
Not Important |
| documents[1].doc_metadata.revised_date | None |
None
|
Not Important |
| documents[1].doc_metadata.version | None |
None
|
Not Important |
| documents[1].doc_metadata.coverage | str |
specific
|
Not Important |
| documents[1].doc_metadata.compliance_status | str |
compliant
|
Not Important |
| documents[2] | dict |
{
"type": "Conflict Minerals",
"level": "Company",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/conflict_minerals_caa1f494.pdf",
"uploaded_at": "2025-12-03T18:08:27.079547",
"doc_metadata": null
}
|
Not Important |
| documents[2].type | str |
Conflict Minerals
|
Not Important |
| documents[2].level | str |
Company
|
Not Important |
| documents[2].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/_company/conflict_minerals_caa1f494.pdf
|
Not Important |
| documents[2].uploaded_at | str |
2025-12-03T18:08:27.079547
|
Not Important |
| documents[2].doc_metadata | None |
None
|
Not Important |
| documents[3] | dict |
{
"type": "California Proposition 65",
"level": "Company",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/california_proposition_65_8e8146f6.pdf",
"uploaded_at": "2025-12-03T18:08:27.079551",
"doc_metadata": null
}
|
Not Important |
| documents[3].type | str |
California Proposition 65
|
Not Important |
| documents[3].level | str |
Company
|
Not Important |
| documents[3].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/_company/california_proposition_65_8e8146f6.pdf
|
Not Important |
| documents[3].uploaded_at | str |
2025-12-03T18:08:27.079551
|
Not Important |
| documents[3].doc_metadata | None |
None
|
Not Important |
| documents[4] | dict |
{
"type": "TSCA",
"level": "Company",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/tsca_42bcc7a4.pdf",
"uploaded_at": "2025-12-03T18:08:27.079555",
"doc_metadata": null
}
|
Not Important |
| documents[4].type | str |
TSCA
|
Not Important |
| documents[4].level | str |
Company
|
Not Important |
| documents[4].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/_company/tsca_42bcc7a4.pdf
|
Not Important |
| documents[4].uploaded_at | str |
2025-12-03T18:08:27.079555
|
Not Important |
| documents[4].doc_metadata | None |
None
|
Not Important |
| documents[5] | dict |
{
"type": "Datasheet",
"level": "Component",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/datasheet_b76ea769.pdf",
"uploaded_at": "2025-12-03T18:08:41.008113",
"doc_metadata": null
}
|
Not Important |
| documents[5].type | str |
Datasheet
|
Not Important |
| documents[5].level | str |
Component
|
Not Important |
| documents[5].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/datasheet_b76ea769.pdf
|
Not Important |
| documents[5].uploaded_at | str |
2025-12-03T18:08:41.008113
|
Not Important |
| documents[5].doc_metadata | None |
None
|
Not Important |
| documents[6] | dict |
{
"type": "RoHS",
"level": "Component",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_75ab3f76.pdf",
"uploaded_at": "2025-12-03T18:08:41.008402",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
}
|
Not Important |
| documents[6].type | str |
RoHS
|
Not Important |
| documents[6].level | str |
Component
|
Not Important |
| documents[6].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_75ab3f76.pdf
|
Not Important |
| documents[6].uploaded_at | str |
2025-12-03T18:08:41.008402
|
Not Important |
| documents[6].doc_metadata | dict |
{
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
|
Not Important |
| documents[6].doc_metadata.is_approved | bool |
True
|
Not Important |
| documents[6].doc_metadata.date_of_issue | str |
2024-05-13
|
Not Important |
| documents[6].doc_metadata.revised_date | None |
None
|
Not Important |
| documents[6].doc_metadata.version | str |
RoHS III
|
Not Important |
| documents[6].doc_metadata.coverage | str |
specific
|
Not Important |
| documents[6].doc_metadata.compliance_status | str |
compliant_with_exemptions
|
Not Important |
| documents[7] | dict |
{
"type": "Halogen-Free",
"level": "Series",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/halogen-free_1c89b3e7.pdf",
"uploaded_at": "2025-12-03T18:08:41.008547",
"doc_metadata": null
}
|
Not Important |
| documents[7].type | str |
Halogen-Free
|
Not Important |
| documents[7].level | str |
Series
|
Not Important |
| documents[7].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/halogen-free_1c89b3e7.pdf
|
Not Important |
| documents[7].uploaded_at | str |
2025-12-03T18:08:41.008547
|
Not Important |
| documents[7].doc_metadata | None |
None
|
Not Important |
| documents[8] | dict |
{
"type": "REACH",
"level": "Series",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_be38c8a6.pdf",
"uploaded_at": "2025-12-03T18:08:43.043987",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2025-02-04",
"revised_date": null,
"version": null,
"coverage": "specific",
"compliance_status": "compliant"
}
}
|
Not Important |
| documents[8].type | str |
REACH
|
Not Important |
| documents[8].level | str |
Series
|
Not Important |
| documents[8].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_be38c8a6.pdf
|
Not Important |
| documents[8].uploaded_at | str |
2025-12-03T18:08:43.043987
|
Not Important |
| documents[8].doc_metadata | dict |
{
"is_approved": true,
"date_of_issue": "2025-02-04",
"revised_date": null,
"version": null,
"coverage": "specific",
"compliance_status": "compliant"
}
|
Not Important |
| documents[8].doc_metadata.is_approved | bool |
True
|
Not Important |
| documents[8].doc_metadata.date_of_issue | str |
2025-02-04
|
Not Important |
| documents[8].doc_metadata.revised_date | None |
None
|
Not Important |
| documents[8].doc_metadata.version | None |
None
|
Not Important |
| documents[8].doc_metadata.coverage | str |
specific
|
Not Important |
| documents[8].doc_metadata.compliance_status | str |
compliant
|
Not Important |
| documents[9] | dict |
{
"type": "REACH",
"level": "Series",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_89f2a1db.pdf",
"uploaded_at": "2025-12-03T18:08:43.044217",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2025-02-04",
"revised_date": null,
"version": null,
"coverage": "specific",
"compliance_status": "compliant"
}
}
|
Not Important |
| documents[9].type | str |
REACH
|
Not Important |
| documents[9].level | str |
Series
|
Not Important |
| documents[9].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/reach_89f2a1db.pdf
|
Not Important |
| documents[9].uploaded_at | str |
2025-12-03T18:08:43.044217
|
Not Important |
| documents[9].doc_metadata | dict |
{
"is_approved": true,
"date_of_issue": "2025-02-04",
"revised_date": null,
"version": null,
"coverage": "specific",
"compliance_status": "compliant"
}
|
Not Important |
| documents[9].doc_metadata.is_approved | bool |
True
|
Not Important |
| documents[9].doc_metadata.date_of_issue | str |
2025-02-04
|
Not Important |
| documents[9].doc_metadata.revised_date | None |
None
|
Not Important |
| documents[9].doc_metadata.version | None |
None
|
Not Important |
| documents[9].doc_metadata.coverage | str |
specific
|
Not Important |
| documents[9].doc_metadata.compliance_status | str |
compliant
|
Not Important |
| documents[10] | dict |
{
"type": "RoHS Exempt",
"level": "Series",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_621bb13a.pdf",
"uploaded_at": "2025-12-03T18:08:43.044426",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
}
|
Not Important |
| documents[10].type | str |
RoHS Exempt
|
Not Important |
| documents[10].level | str |
Series
|
Not Important |
| documents[10].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_621bb13a.pdf
|
Not Important |
| documents[10].uploaded_at | str |
2025-12-03T18:08:43.044426
|
Not Important |
| documents[10].doc_metadata | dict |
{
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
|
Not Important |
| documents[10].doc_metadata.is_approved | bool |
True
|
Not Important |
| documents[10].doc_metadata.date_of_issue | str |
2024-05-13
|
Not Important |
| documents[10].doc_metadata.revised_date | None |
None
|
Not Important |
| documents[10].doc_metadata.version | str |
RoHS III
|
Not Important |
| documents[10].doc_metadata.coverage | str |
specific
|
Not Important |
| documents[10].doc_metadata.compliance_status | str |
compliant_with_exemptions
|
Not Important |
| documents[11] | dict |
{
"type": "RoHS Exempt",
"level": "Series",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_225fdd52.pdf",
"uploaded_at": "2025-12-03T18:08:43.044660",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
}
|
Not Important |
| documents[11].type | str |
RoHS Exempt
|
Not Important |
| documents[11].level | str |
Series
|
Not Important |
| documents[11].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_225fdd52.pdf
|
Not Important |
| documents[11].uploaded_at | str |
2025-12-03T18:08:43.044660
|
Not Important |
| documents[11].doc_metadata | dict |
{
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
|
Not Important |
| documents[11].doc_metadata.is_approved | bool |
True
|
Not Important |
| documents[11].doc_metadata.date_of_issue | str |
2024-05-13
|
Not Important |
| documents[11].doc_metadata.revised_date | None |
None
|
Not Important |
| documents[11].doc_metadata.version | str |
RoHS III
|
Not Important |
| documents[11].doc_metadata.coverage | str |
specific
|
Not Important |
| documents[11].doc_metadata.compliance_status | str |
compliant_with_exemptions
|
Not Important |
| documents[12] | dict |
{
"type": "RoHS Exempt",
"level": "Series",
"url": "https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_807860ec.pdf",
"uploaded_at": "2025-12-03T18:08:43.044814",
"doc_metadata": {
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
}
|
Not Important |
| documents[12].type | str |
RoHS Exempt
|
Not Important |
| documents[12].level | str |
Series
|
Not Important |
| documents[12].url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/RC0603FR-0710KL/rohs_exempt_807860ec.pdf
|
Not Important |
| documents[12].uploaded_at | str |
2025-12-03T18:08:43.044814
|
Not Important |
| documents[12].doc_metadata | dict |
{
"is_approved": true,
"date_of_issue": "2024-05-13",
"revised_date": null,
"version": "RoHS III",
"coverage": "specific",
"compliance_status": "compliant_with_exemptions"
}
|
Not Important |
| documents[12].doc_metadata.is_approved | bool |
True
|
Not Important |
| documents[12].doc_metadata.date_of_issue | str |
2024-05-13
|
Not Important |
| documents[12].doc_metadata.revised_date | None |
None
|
Not Important |
| documents[12].doc_metadata.version | str |
RoHS III
|
Not Important |
| documents[12].doc_metadata.coverage | str |
specific
|
Not Important |
| documents[12].doc_metadata.compliance_status | str |
compliant_with_exemptions
|
Not Important |
| compliance_analysis | dict |
{
"mpn": "RC0603FR-0710KL",
"rohs_analysis": {
"manufacturer": "YAGEO",
"mpn_mentioned": true,
"mpn_coverage": "specific",
"product_family": "R-CHIP (RC Series)",
"is_approved": true,
"compliance_status": "compliant_with_exemptions",
"version": {
"name": "RoHS III",
"date": "2015-06-04",
"details": "Directive (EU) 2015/863"
},
"date_of_issue": "2024-05-13",
"revised_date": null,
"exclusions": {
"has_exclusions": false,
|
Not Important |
| compliance_analysis.mpn | str |
RC0603FR-0710KL
|
Not Important |
| compliance_analysis.rohs_analysis | dict |
{
"manufacturer": "YAGEO",
"mpn_mentioned": true,
"mpn_coverage": "specific",
"product_family": "R-CHIP (RC Series)",
"is_approved": true,
"compliance_status": "compliant_with_exemptions",
"version": {
"name": "RoHS III",
"date": "2015-06-04",
"details": "Directive (EU) 2015/863"
},
"date_of_issue": "2024-05-13",
"revised_date": null,
"exclusions": {
"has_exclusions": false,
"uses_substances": false,
"used_substances": [],
"reasons": null,
"c
|
Not Important |
| compliance_analysis.rohs_analysis.manufacturer | str |
YAGEO
|
Not Important |
| compliance_analysis.rohs_analysis.mpn_mentioned | bool |
True
|
Not Important |
| compliance_analysis.rohs_analysis.mpn_coverage | str |
specific
|
Not Important |
| compliance_analysis.rohs_analysis.product_family | str |
R-CHIP (RC Series)
|
Not Important |
| compliance_analysis.rohs_analysis.is_approved | bool |
True
|
Not Important |
| compliance_analysis.rohs_analysis.compliance_status | str |
compliant_with_exemptions
|
Not Important |
| compliance_analysis.rohs_analysis.version | dict |
{
"name": "RoHS III",
"date": "2015-06-04",
"details": "Directive (EU) 2015/863"
}
|
Not Important |
| compliance_analysis.rohs_analysis.version.name | str |
RoHS III
|
Not Important |
| compliance_analysis.rohs_analysis.version.date | str |
2015-06-04
|
Not Important |
| compliance_analysis.rohs_analysis.version.details | str |
Directive (EU) 2015/863
|
Not Important |
| compliance_analysis.rohs_analysis.date_of_issue | str |
2024-05-13
|
Not Important |
| compliance_analysis.rohs_analysis.revised_date | None |
None
|
Not Important |
| compliance_analysis.rohs_analysis.exclusions | dict |
{
"has_exclusions": false,
"uses_substances": false,
"used_substances": [],
"reasons": null,
"conditions": null
}
|
Not Important |
| compliance_analysis.rohs_analysis.exclusions.has_exclusions | bool |
False
|
Not Important |
| compliance_analysis.rohs_analysis.exclusions.uses_substances | bool |
False
|
Not Important |
| compliance_analysis.rohs_analysis.exclusions.used_substances | list |
[]
|
Not Important |
| compliance_analysis.rohs_analysis.exclusions.reasons | None |
None
|
Not Important |
| compliance_analysis.rohs_analysis.exclusions.conditions | None |
None
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions | dict |
{
"has_exemptions": true,
"uses_substances": true,
"used_substances": [
{
"name": "Lead",
"cas_number": "7439-92-1",
"concentration": null,
"purpose": "In glass or ceramic matrix",
"threshold_exceeded": true
}
],
"exemption_codes": [
"7(c)-I",
"10(a)"
],
"expiry_dates": null,
"geographic_scope": [
"EU",
"China"
],
"conditions": "Lead in a glass or ceramic, or in a glass or ceramic matrix compound"
}
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.has_exemptions | bool |
True
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.uses_substances | bool |
True
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.used_substances | list |
[
{
"name": "Lead",
"cas_number": "7439-92-1",
"concentration": null,
"purpose": "In glass or ceramic matrix",
"threshold_exceeded": true
}
]
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.used_substances[0] | dict |
{
"name": "Lead",
"cas_number": "7439-92-1",
"concentration": null,
"purpose": "In glass or ceramic matrix",
"threshold_exceeded": true
}
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.used_substances[0].name | str |
Lead
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.used_substances[0].cas_number | str |
7439-92-1
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.used_substances[0].concentration | None |
None
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.used_substances[0].purpose | str |
In glass or ceramic matrix
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.used_substances[0].threshold_exceeded | bool |
True
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.exemption_codes | list |
[
"7(c)-I",
"10(a)"
]
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.exemption_codes[0] | str |
7(c)-I
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.exemption_codes[1] | str |
10(a)
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.expiry_dates | None |
None
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.geographic_scope | list |
[
"EU",
"China"
]
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.geographic_scope[0] | str |
EU
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.geographic_scope[1] | str |
China
|
Not Important |
| compliance_analysis.rohs_analysis.exemptions.conditions | str |
Lead in a glass or ceramic, or in a glass or ceramic matrix compound
|
Not Important |
| compliance_analysis.rohs_analysis.version_too_old | bool |
False
|
Not Important |
| compliance_analysis.rohs_analysis.critical_substance_alert | bool |
False
|
Not Important |
| compliance_analysis.rohs_analysis.exist_exceptions_limitations | bool |
True
|
Not Important |
| compliance_analysis.rohs_analysis.source | dict |
{
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf",
"document_type": "RoHS Exempt",
"document_level": "series",
"extraction_confidence": "high"
}
|
Not Important |
| compliance_analysis.rohs_analysis.source.document_url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/_company/rohs_e7cb2ba7.pdf
|
Not Important |
| compliance_analysis.rohs_analysis.source.document_type | str |
RoHS Exempt
|
Not Important |
| compliance_analysis.rohs_analysis.source.document_level | str |
series
|
Not Important |
| compliance_analysis.rohs_analysis.source.extraction_confidence | str |
high
|
Not Important |
| compliance_analysis.reach_analysis | dict |
{
"manufacturer": "YAGEO",
"mpn_mentioned": true,
"mpn_coverage": "specific",
"product_family": "Chip Resistor",
"is_approved": true,
"compliance_status": "compliant",
"version": {
"name": "REACH",
"date": "2006-12-18",
"details": "Regulation (EC) No 1907/2006"
},
"date_of_issue": "2025-02-04",
"revised_date": null,
"exclusions": {
"has_exclusions": false,
"uses_substances": false,
"used_substances": [],
"reasons": null,
"conditions": null
|
Not Important |
| compliance_analysis.reach_analysis.manufacturer | str |
YAGEO
|
Not Important |
| compliance_analysis.reach_analysis.mpn_mentioned | bool |
True
|
Not Important |
| compliance_analysis.reach_analysis.mpn_coverage | str |
specific
|
Not Important |
| compliance_analysis.reach_analysis.product_family | str |
Chip Resistor
|
Not Important |
| compliance_analysis.reach_analysis.is_approved | bool |
True
|
Not Important |
| compliance_analysis.reach_analysis.compliance_status | str |
compliant
|
Not Important |
| compliance_analysis.reach_analysis.version | dict |
{
"name": "REACH",
"date": "2006-12-18",
"details": "Regulation (EC) No 1907/2006"
}
|
Not Important |
| compliance_analysis.reach_analysis.version.name | str |
REACH
|
Not Important |
| compliance_analysis.reach_analysis.version.date | str |
2006-12-18
|
Not Important |
| compliance_analysis.reach_analysis.version.details | str |
Regulation (EC) No 1907/2006
|
Not Important |
| compliance_analysis.reach_analysis.date_of_issue | str |
2025-02-04
|
Not Important |
| compliance_analysis.reach_analysis.revised_date | None |
None
|
Not Important |
| compliance_analysis.reach_analysis.exclusions | dict |
{
"has_exclusions": false,
"uses_substances": false,
"used_substances": [],
"reasons": null,
"conditions": null
}
|
Not Important |
| compliance_analysis.reach_analysis.exclusions.has_exclusions | bool |
False
|
Not Important |
| compliance_analysis.reach_analysis.exclusions.uses_substances | bool |
False
|
Not Important |
| compliance_analysis.reach_analysis.exclusions.used_substances | list |
[]
|
Not Important |
| compliance_analysis.reach_analysis.exclusions.reasons | None |
None
|
Not Important |
| compliance_analysis.reach_analysis.exclusions.conditions | None |
None
|
Not Important |
| compliance_analysis.reach_analysis.exemptions | None |
None
|
Not Important |
| compliance_analysis.reach_analysis.version_too_old | bool |
False
|
Not Important |
| compliance_analysis.reach_analysis.critical_substance_alert | bool |
False
|
Not Important |
| compliance_analysis.reach_analysis.exist_exceptions_limitations | bool |
False
|
Not Important |
| compliance_analysis.reach_analysis.source | dict |
{
"document_url": "https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf",
"document_type": "REACH",
"document_level": "specific",
"extraction_confidence": "high"
}
|
Not Important |
| compliance_analysis.reach_analysis.source.document_url | str |
https://beta.certain.li/doc/declarations/yageo_corporation/_company/reach_e43f60ba.pdf
|
Not Important |
| compliance_analysis.reach_analysis.source.document_type | str |
REACH
|
Not Important |
| compliance_analysis.reach_analysis.source.document_level | str |
specific
|
Not Important |
| compliance_analysis.reach_analysis.source.extraction_confidence | str |
high
|
Not Important |
| compliance_analysis.reach_analysis.svhc_present | bool |
False
|
Not Important |
| compliance_analysis.reach_analysis.candidate_list_date | str |
2025-06-25
|
Not Important |
| compliance_analysis.reach_analysis.svhc_substances | list |
[]
|
Not Important |
| compliance_analysis.reach_analysis.svhc_cas_numbers | list |
[]
|
Not Important |
| compliance_analysis.material_composition | dict |
{
"substances": [
{
"name": "Lead",
"cas_number": "7439-92-1",
"concentration": "< 90 ppm",
"purpose": "Termination coating",
"threshold_exceeded": false
},
{
"name": "Cadmium",
"cas_number": "7440-43-9",
"concentration": "< 2 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"name": "Mercury",
"cas_number": "7439-97-6",
"concentration": "< 2 ppm",
"purpose": "R
|
Not Important |
| compliance_analysis.material_composition.substances | list |
[
{
"name": "Lead",
"cas_number": "7439-92-1",
"concentration": "< 90 ppm",
"purpose": "Termination coating",
"threshold_exceeded": false
},
{
"name": "Cadmium",
"cas_number": "7440-43-9",
"concentration": "< 2 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
},
{
"name": "Mercury",
"cas_number": "7439-97-6",
"concentration": "< 2 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": fa
|
Not Important |
| compliance_analysis.material_composition.substances[0] | dict |
{
"name": "Lead",
"cas_number": "7439-92-1",
"concentration": "< 90 ppm",
"purpose": "Termination coating",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[0].name | str |
Lead
|
Not Important |
| compliance_analysis.material_composition.substances[0].cas_number | str |
7439-92-1
|
Not Important |
| compliance_analysis.material_composition.substances[0].concentration | str |
< 90 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[0].purpose | str |
Termination coating
|
Not Important |
| compliance_analysis.material_composition.substances[0].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.substances[1] | dict |
{
"name": "Cadmium",
"cas_number": "7440-43-9",
"concentration": "< 2 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[1].name | str |
Cadmium
|
Not Important |
| compliance_analysis.material_composition.substances[1].cas_number | str |
7440-43-9
|
Not Important |
| compliance_analysis.material_composition.substances[1].concentration | str |
< 2 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[1].purpose | str |
Restricted substance check
|
Not Important |
| compliance_analysis.material_composition.substances[1].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.substances[2] | dict |
{
"name": "Mercury",
"cas_number": "7439-97-6",
"concentration": "< 2 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[2].name | str |
Mercury
|
Not Important |
| compliance_analysis.material_composition.substances[2].cas_number | str |
7439-97-6
|
Not Important |
| compliance_analysis.material_composition.substances[2].concentration | str |
< 2 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[2].purpose | str |
Restricted substance check
|
Not Important |
| compliance_analysis.material_composition.substances[2].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.substances[3] | dict |
{
"name": "Hexavalent Chromium",
"cas_number": "18540-29-9",
"concentration": "< 8 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[3].name | str |
Hexavalent Chromium
|
Not Important |
| compliance_analysis.material_composition.substances[3].cas_number | str |
18540-29-9
|
Not Important |
| compliance_analysis.material_composition.substances[3].concentration | str |
< 8 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[3].purpose | str |
Restricted substance check
|
Not Important |
| compliance_analysis.material_composition.substances[3].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.substances[4] | dict |
{
"name": "PBBs",
"cas_number": null,
"concentration": "< 5 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[4].name | str |
PBBs
|
Not Important |
| compliance_analysis.material_composition.substances[4].cas_number | None |
None
|
Not Important |
| compliance_analysis.material_composition.substances[4].concentration | str |
< 5 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[4].purpose | str |
Restricted substance check
|
Not Important |
| compliance_analysis.material_composition.substances[4].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.substances[5] | dict |
{
"name": "PBDE",
"cas_number": null,
"concentration": "< 5 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[5].name | str |
PBDE
|
Not Important |
| compliance_analysis.material_composition.substances[5].cas_number | None |
None
|
Not Important |
| compliance_analysis.material_composition.substances[5].concentration | str |
< 5 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[5].purpose | str |
Restricted substance check
|
Not Important |
| compliance_analysis.material_composition.substances[5].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.substances[6] | dict |
{
"name": "DEHP",
"cas_number": "117-81-7",
"concentration": "< 50 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[6].name | str |
DEHP
|
Not Important |
| compliance_analysis.material_composition.substances[6].cas_number | str |
117-81-7
|
Not Important |
| compliance_analysis.material_composition.substances[6].concentration | str |
< 50 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[6].purpose | str |
Restricted substance check
|
Not Important |
| compliance_analysis.material_composition.substances[6].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.substances[7] | dict |
{
"name": "DBP",
"cas_number": "84-74-2",
"concentration": "< 50 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[7].name | str |
DBP
|
Not Important |
| compliance_analysis.material_composition.substances[7].cas_number | str |
84-74-2
|
Not Important |
| compliance_analysis.material_composition.substances[7].concentration | str |
< 50 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[7].purpose | str |
Restricted substance check
|
Not Important |
| compliance_analysis.material_composition.substances[7].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.substances[8] | dict |
{
"name": "BBP",
"cas_number": "85-68-7",
"concentration": "< 50 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[8].name | str |
BBP
|
Not Important |
| compliance_analysis.material_composition.substances[8].cas_number | str |
85-68-7
|
Not Important |
| compliance_analysis.material_composition.substances[8].concentration | str |
< 50 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[8].purpose | str |
Restricted substance check
|
Not Important |
| compliance_analysis.material_composition.substances[8].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.substances[9] | dict |
{
"name": "DIBP",
"cas_number": "84-69-5",
"concentration": "< 50 ppm",
"purpose": "Restricted substance check",
"threshold_exceeded": false
}
|
Not Important |
| compliance_analysis.material_composition.substances[9].name | str |
DIBP
|
Not Important |
| compliance_analysis.material_composition.substances[9].cas_number | str |
84-69-5
|
Not Important |
| compliance_analysis.material_composition.substances[9].concentration | str |
< 50 ppm
|
Not Important |
| compliance_analysis.material_composition.substances[9].purpose | str |
Restricted substance check
|
Not Important |
| compliance_analysis.material_composition.substances[9].threshold_exceeded | bool |
False
|
Not Important |
| compliance_analysis.material_composition.format_standard | str |
Manufacturer Declaration
|
Not Important |
| compliance_analysis.material_composition.date_of_issue | str |
2024-05-13
|
Not Important |
| compliance_analysis.material_composition.mpn_verified | bool |
True
|
Not Important |
| compliance_analysis.material_composition.source | dict |
{
"document_url": "RC0603FR-0710KL-RoHS Exempt",
"document_type": "RoHS Exempt",
"document_level": "series",
"extraction_confidence": "medium"
}
|
Not Important |
| compliance_analysis.material_composition.source.document_url | str |
RC0603FR-0710KL-RoHS Exempt
|
Not Important |
| compliance_analysis.material_composition.source.document_type | str |
RoHS Exempt
|
Not Important |
| compliance_analysis.material_composition.source.document_level | str |
series
|
Not Important |
| compliance_analysis.material_composition.source.extraction_confidence | str |
medium
|
Not Important |
| compliance_analysis.overall_compliance_status | str |
compliant_with_exemptions
|
Critical |
| compliance_analysis.compliance_summary | str |
RoHS Compliant with Exemptions 7(c)-I and 10(a). REACH Compliant (SVHC < 0.1%). Source: RoHS Exempt - 'It is hereby certified that all of the electronic components stated above are compliant with EU RoHS... We also claim for the following exemption... 7(c)-1: Electrical and electronics compounds... containing Lead in a glass or ceramic...'. REACH Declaration - 'COMPLY WITH the Regulations of Substances of Very High Concern... (SVHC<0.1%)'. The MPN RC0603FR-0710KL belongs to the RC series covered by the RoHS exemption document.
|
Not Important |
| compliance_analysis.alerts | list |
[
"RoHS Exemption 7(c)-I (Lead in glass/ceramic) is claimed.",
"RoHS Exemption 10(a) is also listed in the document but is typically for ELV or specific applications; 7(c)-I is the primary RoHS exemption for resistors.",
"Full material composition breakdown (IPC-1752) not available; partial substance data extracted from RoHS/REACH certificates."
]
|
Not Important |
| compliance_analysis.alerts[0] | str |
RoHS Exemption 7(c)-I (Lead in glass/ceramic) is claimed.
|
Not Important |
| compliance_analysis.alerts[1] | str |
RoHS Exemption 10(a) is also listed in the document but is typically for ELV or specific applications; 7(c)-I is the primary RoHS exemption for resistors.
|
Not Important |
| compliance_analysis.alerts[2] | str |
Full material composition breakdown (IPC-1752) not available; partial substance data extracted from RoHS/REACH certificates.
|
Not Important |
| compliance_analysis.critical_issues | list |
[]
|
Not Important |
| compliance_analysis.confidence_level | str |
high
|
Not Important |
| compliance_analysis.documents_analyzed | int |
9
|
Not Important |
| compliance_analysis.created_at | str |
2025-12-03T18:12:05.351829
|
Not Important |
| processing_time_ms | int |
0
|
Not Important |